Passive Fire Box

Passive Fire Box Right Front Room

Right Front 1a

Right Front 5a

Right Front 6a

put a new unicollar that juts out over the inverted (juts into the box) unicollar. fill middle of the space with black fire paste.

Passive Fire Box Left Rear Room


Left Rear 5a

put a new unicollar that juts out over the inverted (juts into the box) unicollar. fill middle of the space with black fire paste.

Passive Fire Box Left Front Room


Left Front 1a

Left Front 4a

1x PEX wrap in unicollar jutting out of the wall. Do not invert. Inside space fill with black paste and fill outside gap with while fire mastix. Separate from other cables by 50-100mm

Electrical cables (14X) and solar panel cables. wrap in unicollar jutting out of the wall or PROMASEAL FCW40 wall collar. Inside space fill with black paste and fill outside gap with while fire mastix. Separate from other cables by 50-100mm

Network cable (1x), Optic fibre cable (1x) wrap in white fire mastix. Separate from other cables by 50-100mm